Add to Cart
The standard model of the empty feeder is that the feeding time is controlled by a floating rod. The feeding slider is installed on the punching slider. When the punching slider drives the feeding rod to press the floating rod to a certain extent, the feeding machine starts feeding.
If the stroke of the press is too short or the feed length is long, the use of the floating rod to control the feeding time will appear too late, resulting in the phenomenon that the feeder is not in place.
In this case, the feeding solenoid valve should be installed to control the feeding time. Since the feeding time is controlled by the solenoid valve, the feeding angle can be adjusted arbitrarily.
Ruihui air feeder standard machine installed feeding solenoid valve required accessories: instead of a floating rod plug, a five-way solenoid valve, one internal three-way one, the outer teeth straight through two quick joints.
The trachea is 300mm, the double-core line is 5 meters long, one waterproof sealant is used, one solenoid valve plug is used, and the outer teeth are straight through two.
If the punch does not have a cam set, a micro switch, a cam piece, and a set of fixed micro switch brackets are required.
Feeder solenoid valve combination installation:
1. Install the middle hole of the three holes of the solenoid valve through the outer teeth, and plug the B hole with the plug screw. The A hole is equipped with an external tooth straight through the quick joint.
2. Fold the air feeder air supply connector and install the inner teeth tee. Then install the two outer teeth directly into the other two teeth of the other three teeth, and then attach the air to the air inlet of the air feeder. Upper solenoid valve.
3. Replace the floating rod plug with the external joint quick joint, then install it into the original place of the floating rod, insert the end of the trachea into the quick joint of the plug outer teeth, and insert the other end of the trachea into the outer joint of the electromagnetic front valve. Where.
4. Then connect the two core wires to the two terminals of the solenoid valve, and the core is connected to one terminal of the punching cam micro switch.
The other terminal is connected to the zero line of the power supply, and then the other core wire on the solenoid valve is directly connected to the power line of the power supply.
5. Finally adjust the cam angle to make the feeding time suitable for stamping production.
Specification:
Model | MAC2-400 | MAC2-500 | MAC2-600 | MAC2-800 | ||
Stock Width(mm) | 50-400 | 50-500 | 50-600 | 50-800 | ||
Stock Thickness(mm) | 0.3~3.2 | 0.3-3.2 | 0.3-3.2 | -3.2 | ||
Max.Coil Weight(kg) | 3000 | 3000 | 3000 | 5000 | 5000 | 7000 |
Max.Coil O.D.(mm) | 1200 | 1200 | 1200 | |||
Coil I.D.(mm) | 8 | 8 | 508 | 508 | ||
Feed Length(mm) | ~500* | ~500* | ~500* | ~500* | ||
Max. Line Speed(m/min) | 16-24 | 16-24 | 16-24 | 16-24 | ||
Work Roll Number(pieces) | upper 6 lower 5 | upper 6 lower 5 | upper 6 lower 5 | upper 6 lower 5 | ||
Feed Roll Number(set) | 1 | 1 | 1 | 1 | ||
Main Motor(kw) | AC2.9 | AC2.9 | AC4.4 | AC4.4 | ||
Mandrel Expansion | hydraulic | hydraulic | hydraulic | hydraulic | ||
Reel Motor(kw) | 1.5 | 1.5 | 1.5 | 2.2 | 2.2 | 3.7 |
Power(V) | 3 Phase 220V/380V/50HZ | |||||
Operating Air(Mpa) | 0.49 | 0.49 | 0.49 | 0.49 |
Straigtening performance:
tock Thicknees (mm) | Stock Width (mm) | |||
0.3 | 400 | 500 | 600 | 800 |
0.4 | ||||
0.6 | ||||
0.8 | ||||
1.0 | ||||
1.2 | ||||
1.4 | ||||
1.6 | 470 | 470 | ||
1.8 | 400 | 400 | ||
2.0 | 360 | 360 | ||
2.3 | 300 | 300 | 300 | 300 |
2.5 | 230 | 230 | 230 | 230 |
2.8 | 150 | 150 | 150 | 150 |
3.2 | 110 | 110 | 110 | 110 |
*1:(Pneumatic):Option in case of pneumatic mandrel expansion is provi